WC flush plate for Prevista Visign for Style 26
for all Prevista concealed cisterns
Year built (from): | 1. 01. 2024 |
Trade mark rights exist for this document; for further information, go to viega.com/legal .
The information in this instruction manual is directed at the following groups of people:
Heating and plumbing experts and trained personnel
Consumers
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns of possible life-threatening injury.
This symbol warns of possible serious injury.
This symbol warns of possible injury.
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g. EN) and/or in Germany (e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The following standards and regulations apply to Germany / Europe and are provided as a support feature.
Scope / Notice | Regulations applicable in Germany |
---|---|
Flush flow | DIN 3265 |
Noise class | DIN 4109 |
The flush plate is intended for the actuation of flushes on Viega concealed cisterns.
Installation is possible in all Prevista concealed cisterns.
The flush volume for the flush actuation is:
Large flush volume: approx. 3.5–7.5 litres
For the setting of the flush see Setting the flush volume .
Requirements:
The cistern is fitted into the pre-wall.
The pre-wall is tiled.
Grip the shaft cover by the troughs.
Remove the shaft cover.
Cut into the corners of the inspection shaft.
Fold the sides of the inspection shaft outwards up to the tile level and snap them off.
Turn the site protection panel lock 90° anti-clockwise.
Remove the site protection panel.
Close the corner valve.
The maximum torque is 4 Nm.
Loosen the flexible hose on the filling valve.
For setting the flush volume, see Setting the flush volume .
Open the corner valve for a few seconds to flush the pipe.
Close the corner valve.
The maximum torque is 4 Nm.
Connect the flexible hose to the filling valve.
Re-open the corner valve.
Check the corner valve and the filling valve for leak tightness.
Insert the site protection panel into the cistern.
Turn the site protection panel's lock by 90° clockwise.
Put on the installation frame.
Insert the retaining bolts.
Turn the retaining bolts by 90° in a clockwise direction.
Align the installation frame.
To fix the retaining pins, turn the safety rings in a clockwise direction.
If you are not sure which cistern is installed, identify it by means of the following dimensions.
3H concealed cistern
Concealed cistern 3L
Concealed cistern 3F
For installation from the front into the concealed cisterns 3H, 3L, 3F.
Determine the distance for the actuating rod.
Cistern 3H and 3L.
If necessary, cut the actuating rod to length.
0: 75–50 mm
1: 50–25 mm
2: 25–10 mm
Cistern 3F.
If necessary, cut the actuating rod to length.
1: 75–55 mm
2: 55–35 mm
3: 35–15 mm
4: 15–10 mm
For installation from above into concealed cistern 3L.
Determine the distance for the actuating rod.
If necessary, cut the actuating rod to length.
0: 60–45 mm
1: 45–25 mm
2: 25–10 mm
Insert the actuating rod as far as it will go.
Align the actuating rod.
Turn the actuating rod clockwise by 90°.
Mount the flush plate.
The flush plate is mounted.
Fold the tabs forward.
Lift the drain valve.
Remove the drain valve through the revision opening.
Set the large flush volume at the drain valve.
Error | Cause | Solution |
---|---|---|
The WC does not flush. | The cistern is not yet completely full. | Wait until the cistern is sufficiently full. |
There is no water in the cistern. The corner valve is closed. | Open the corner valve. | |
The WC flush runs through. | The seal at the filling valve is dirty or damaged. | Check the seal, replace if necessary. |
The seal at the drain valve is dirty or damaged. | Check the seal, replace if necessary. |
Use normal soap or a mild cleaning agent for regular care and prevention of lime scale on the flush plate. Under no circumstances should scouring agent or scratching objects be used.
Strong stains can be removed using typical household cleaner. Rinse the detergent thoroughly with clear water after the prescribed exposure time. There should be no residue on the components.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.