Visign for More 103 equipment set
for urinal flushing system
Baujahr (ab): | 1.12.2014 |
Trade mark rights exist for this document; for further information, go to viega.com/legal .
The information in this instruction manual is directed at the following groups of people:
Heating and sanitary professionals and trained personnel
Qualified electricians
Operators
Consumers
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns of possible life-threatening injury.
This symbol warns of possible serious injury.
This symbol warns of possible injury.
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g. EN) and/or in Germany (e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The following standards and regulations apply to Germany / Europe and are provided as a support feature.
Scope / Notice | Regulations applicable in Germany |
---|---|
Flush flow | DIN 3265 |
Noise class | DIN 4109 |
Danger due to electrical current
An electric shock can lead to burns and serious injury and even death.
Work on the electrics may only be carried out by trained electricians.
Switch off the mains voltage before connecting the power pack.
The equipment set is intended for the contact-free actuation of flushes in urinals.
Physical environmental influences can impair the control function.
The Viega Service Center will answer any further questions on this subject.
The Viega Hygiene+ function actuates a flush after 24 hours without use to prevent stagnation in the potable water lines.
The cartridge valve should be cleaned once a year to ensure fault-free operation. See Cleaning cartridge valve
The product has the following technical data:
Operating voltage |
---|
Magnetic coil |
Flow pressure |
Calculated flow |
Flush flow, see Regulations from section: Technical data |
Noise class, see Regulations from section: Technical data |
Primary 100–240 V AC, 50–60 Hz, 180 mA Secondary 6 V DC/SELV |
6 V |
0.05–0.5 MPa (0.5–5 bar) |
0.3 l/s |
0.3–0.7 l/s |
2 |
Flush actuation takes place without contact via the infrared sensor on the flush plate.
The flush volume can be set in five stages.
In order to actuate a flush, a person must be within the detection area of the infrared sensor for at least 8 seconds.
If a person leaves the detection area, a flush is automatically actuated.
Depending on the setting, the flush duration is between 1 and 20 seconds.
A flush cycle can also be manually actuated by placing a hand in front of the sensor during the first 8 seconds.
Stagnation can lead to the build up of germs (e. g. legionella) in drinking water pipes. It is important to rinse the pipeline regularly to prevent the build up of bacteria. The Viega Hygiene+ function was developed for this reason.
The Viega Hygiene+ function automatically actuates a Hygiene flush after 24 hours without use. The flush volume of the Hygiene flush can be set in five stages.
The system's range of functions can be expanded through the connection of accessories onto the control.
Buttons, switches or photo sensors for triggering the flush can be connected to the control on site via the extension cable model 2241.95.
The cartridge valve remains open as long as the contact via the extension cable is closed.
The overflow protection prevents that the cartridge valve remains open for longer than a minute. The contact must be re-opened to enable a further flush.
The battery compartment model 8351.11 (article number 731 786) can also be connected as an alternative to the power pack.
Range of the infrared sensor
The following settings are possible:
Close range, so that the flush cannot be inadvertently actuated.
Medium range from approx. 450 mm. This setting is the factory setting.
Far range, so that the automatic actuation of a flush also works at a greater distance from the urinal.
Manual flush in close range
If this option is activated, a flush can be actuated in the first 8 seconds of entering the detection area by placing a hand in front of the sensor.
Lid in front of sensor
This setting is for the case that an open lid covers the sensor. The function is deactivated in the factory settings. If the function is activated, a flush cycle is actuated as soon as the lid is removed from the sensor zone.
However, during planning, we still recommend that the lid is not placed in front of the sensor in order to ensure the device works perfectly.
Flush duration
This setting is intended exclusively for the flush duration for the directly actuated flushes. The flush duration for hygiene flushes is set separately.
The flush duration can be set in 5 steps to reach the required flush volume.
Hygiene flush
The setting determines if a hygiene flush is actuated after 24 hours without use.
Flush duration hygiene flush
The flush duration of the hygiene flush can be set in 5 steps to reach the required flush volume.
If external sensors are to be connected to the control, their connection cables must be laid through to the revision opening before tiling is begun.
The following minimum distances must be complied with to ensure the infrared sensor works perfectly:
A minimum distance of 1000 mm must be maintained to the opposite walls.
If high-gloss wall claddings (polished tiles, mirrors, etc.) are situated opposite, increase the minimum distance to 1500 mm.
A minimum distance of 1500 mm must be maintained to urinals situated opposite with infrared sensors.
The following tools are required for mounting:
Flat-blade screwdriver
Fork spanner (size 17)
Fork spanner (size 32)
Requirements:
the pre-wall element has been mounted
the revision opening is freely accessible
the tiling work is completed.
Open the shut-off with a screw driver for a few seconds to rinse the pipeline.
Re-close shut-off.
Remove seal (SW 17).
Place the cartridge valve on straight and carefully screw in (fine thread).
Screw in cartridge valve (SW 32).
Danger due to electrical current
An electric shock can lead to burns and serious injury and even death.
Only allow electrical work to be carried out by qualified electricians.
Always de-energise the connection cable before work is commenced.
Requirements:
A 230 V mains connection is available on site.
The connection cable is de-energised.
Remove approx. 1 cm of the insulation on the connection cables.
Push the connection cables into the terminals and screw them down.
Connect the terminals of the connection cables and power pack.
Push the power pack into the revision opening.
In the next step, the basic panel of the flush plate must be mounted.
Requirements:
The cartridge valve is mounted.
The power pack is connected.
Align basic panel horizontally and screw together.
Observation of the prescribed connection sequence is required. The power supply must always be connected last, to ensure that all of the connected components function.
Connect the cartridge valve to the control.
If required, additional external sensors can be connected to the control. See Connecting external sensors .
Connect the power pack to the control.
The infrared sensor is calibrated for approx. 10 seconds. While calibrating, ensure you are stood to the side of the panel so that you are not in the sensor’s detection area.
Open shut-off with a screwdriver.
Mount cover plate onto the basic panel.
Damage to property due to excess voltage
If you apply voltage to the connection cable for the external button, you will damage the control.
Do not apply any external voltage!
Requirements:
On site button with closing function or potential-free contact available
Extension cable model 2241.95 available
Remove the jack from the extension cable model 2241.95.
Connect the contact to actuate the flush cycle to the extension cable.
Connect the extension cable to the control.
Continue with the mounting of the flush plate. See Mounting the flush plate .
Programming the control can be carried out for 30 minutes after the supply voltage is applied. The control returns to normal operation after 30 minutes – programming is now blocked. If the settings have to be changed after this time, the control must be disconnected from the power supply for at least 10 seconds.
Observe the following features during programming:
Only one value can be set per programming step.
The settings are retained, even if there is an interruption in the power supply.
The programming procedure can be interrupted without changing the settings by covering the infrared sensor until the flashing signal has stopped for more than 2 seconds.
Requirements:
The control programming block is not active.
Cover the top part of the infrared ring. (e. g. with a finger or a hand).
The LED blinks twice after 10 seconds. Programming mode is active.
The following values can be set by removing the hand:
Remove hand after | Setting |
---|---|
12. blinking signal | close range set |
13. blinking signal | medium range set (factory setting) |
14. blinking signal | long range set |
15. blinking signal | function "Manual flush in close range" ON |
16. blinking signal | function "Manual flush in close range" OFF (factory setting) |
17. blinking signal | function "Urinal cover in front of sensor" ON |
18. blinking signal | function "Urinal cover in front of sensor" OFF (factory setting) |
The LED flashes twice to confirm the setting.
Using the guide values from the table below, you can determine the flush volume on the basis of flow pressure and flush duration:
Flow pressure |
---|
0.1 MPa (1 bar) |
0.2 MPa (2 bar) |
0.3 MPa (3 bar) |
0.4 MPa (4 bar) |
0.5 MPa (5 bar) |
flush duration 2 seconds | flush duration 5 seconds | flush duration 10 seconds | flush duration 15 seconds | flush duration 20 seconds |
---|---|---|---|---|
0.5 l | 1.2 l | 2.1 l | 3.1 l | 4.1 l |
0.7 l | 1.6 l | 3 l | 4.5 l | 5.9 l |
0.9 l | 2 l | 3.7 l | 5.4 l | 7.2 l |
1 l | 2.3 l | 4.3 l | 6.3 l | 8.3 l |
1.2 l | 2.6 l | 4.8 l | 7 l | 9 l |
Requirements:
The programming lock of the control is not active.
Cover the top part of the infrared ring. (e. g. with a finger or a hand).
The LED blinks twice after 10 seconds. Programming mode is active.
The following values can be set by removing the hand:
Remove hand after | Setting |
---|---|
1st blinking signal | flush duration approx. 2 seconds |
2nd blinking signal | flush duration approx. 5 seconds |
3rd blinking signal | flush duration approx. 10 seconds (factory setting) |
4th blinking signal | flush duration approx. 15 seconds |
5th blinking signal | flush duration approx. 20 seconds |
The LED flashes twice as confirmation of the setting.
You can define the hygiene flush volume on the basis of the flow pressure and flush duration using the values in the table:
Flow pressure |
---|
0.1 MPa (1 bar) |
0.2 MPa (2 bar) |
0.3 MPa (3 bar) |
0.4 MPa (4 bar) |
0.5 MPa (5 bar) |
flush duration 2 seconds | flush duration 5 seconds | flush duration 10 seconds | flush duration 15 seconds | flush duration 20 seconds |
---|---|---|---|---|
0.5 l | 1.2 l | 2.1 l | 3.1 l | 4.1 l |
0.7 l | 1.6 l | 3 l | 4.5 l | 5.9 l |
0.9 l | 2 l | 3.7 l | 5.4 l | 7.2 l |
1 l | 2.3 l | 4.3 l | 6.3 l | 8.3 l |
1.2 l | 2.6 l | 4.8 l | 7 l | 9 l |
Requirements:
The programming lock of the control is not active.
Cover the top part of the infrared ring (e. g. with a finger or a hand).
The LED blinks twice after 10 seconds. Programming mode is active.
The following values can be set by removing the hand:
Remove hand after | Setting |
---|---|
6th blinking signal | Hygiene flush OFF |
7th blinking signal | flush duration approx. 2 seconds |
8th blinking signal | flush duration approx. 5 seconds (factory setting) |
9th blinking signal | flush duration approx. 10 seconds |
10th blinking signal | flush duration approx. 15 seconds |
11th blinking signal | flush duration approx. 20 seconds |
The LED flashes twice to confirm the setting.
Error |
---|
Urinal does not flush |
Flush is too weak |
Urinal flush runs through |
Cause | Remedy |
---|---|
No supply voltage | check plug connections |
Shut-off valve closed | Open shut-off valve |
Sensor field dirty or damaged | Clean cover plate, if necessary, replace Care tips |
Cartridge valve dirty or damaged | Clean cartridge valve, if necessary, replace Cleaning cartridge valve |
Control defect | Replace base frame |
The red LED flashes quickly during the first minute after commissioning, although there is no-one in the sensor detection area. Infrared sensor detection area too large. | Reduce detection area Setting the flush |
The red LED flashes in the first minute after commissioning. The flashing does not become quicker even though there is someone in the detection area. Infrared sensor detection area too small. | Increase detection area Setting the flush |
Shut-off valve is not open far enough | Open shut-off valve |
Flow pressure too high | Maximum flow pressure 0.5 MPa (5 bar) |
Flushing time too short | Set flushing time Setting the flush |
Cartridge valve dirty or damaged | Clean cartridge valve, if necessary, replace Cleaning cartridge valve |
Components are fitted in the wrong order | Separate the plug connections and wait 10 seconds. Re-connect the cartridge valve then the power supply. |
Shut-off valve is not open far enough | Open shut-off valve Minimum flow pressure 0.05 MPa (0.5 bar) |
Cartridge valve dirty or damaged | Clean cartridge valve, if necessary, replace Cleaning cartridge valve |
Control defect | Replace base frame |
Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the flush plate. Under no circumstances should scouring agent or scratching objects be used.
Strong stains can be removed using typical household cleaner. Rinse the detergent thoroughly with clear water after the prescribed exposure time. There should be no residue on the components.
To clean the flush plate, the flush actuation function can be briefly deactivated.
Deactivation only becomes possible 30 minutes after connecting the power supply.
Cover the top part of the infrared ring.
The LED blinks twice after 10 seconds.
The LED blinks again after a further 2 seconds.
Remove the cover from the infrared ring within 2 seconds.
The LED blinks twice.
The flush actuation is deactivated for 10 minutes. The LED is lit during this time.
Clean flush plate.
The LED goes out after 10 minutes and a flush is actuated.
The flush actuation is active again.
The cartridge valve may be cleaned, if necessary. Proceed as follows:
Remove the cover plate from the basic panel using the suction foot.
Close shut-off.
Disconnect cartridge valve and power supply from the control.
Unscrew cartridge valve.
Rinse cartridge valve under running water.
Remove coarse dirt with a soft brush.
Place the cartridge valve on straight and carefully screw in (fine thread).
Screw in cartridge valve (SW 32).
Connect the cartridge valve to the control.
Connect the power pack to the control.
The infrared sensor is calibrated for approx. 10 seconds. While calibrating, ensure you are stood to the side of the panel so that you are not in the sensor’s detection area.
Open shut-off with a screwdriver.
Mount cover plate onto the basic panel.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.